Applications, organised by what actually fails
Every application below starts from the failure mode rather than the product name, because that is how the specification gets decided.
HVAC & air handling
Outdoor enclosures, air-handling units, duct and cabinet sealing, vibration isolation for fans.
What decides the specification
UV and ozone exposure, condensation, and a temperature band that swings with season. EPDM is the usual starting point; compression set over the service life matters more than tensile strength.
What we need from you
- Compression set at the actual operating temperature
- Ozone and UV resistance of the specific compound
- Whether the seal is compressed by a fixed gap or a variable one
Pumps, valves & fluid handling
Casing seals, flange gaskets, diaphragms, valve seats, O-rings and custom seals.
What decides the specification
Media resistance dominates. Water and steam point to EPDM; mineral oil and grease to NBR; fuels and solvents to FKM. A pump that sees both oil and outdoor weather needs a design decision, not a compromise compound.
What we need from you
- The exact media, including cleaners and coolants
- Continuous and peak temperature
- Pressure and the compression set allowance
Machinery & vibration isolation
Anti-vibration mounts, bumpers, bellows, machine-guarding seals and flexible couplings.
What decides the specification
Static load per mount, the frequency to isolate and the ambient environment decide the design. Natural rubber is common for fatigue resistance; NBR where oil is present; silicone at high temperature.
What we need from you
- Static load per mount and load distribution
- Running frequency and the target isolation
- Oil, heat and ozone exposure at the mounting point
Enclosures, cabinets & outdoor equipment
Door gaskets, cable entry seals, window seals and edge protection for outdoor cabinets.
What decides the specification
IP rating targets and water ingress dominate. The gasket geometry has to match the enclosure's compression stop, and the compound has to survive the UV dose at the installation latitude.
What we need from you
- Target IP rating and the test method
- UV dose and expected service life
- Whether the door is opened regularly (abrasion and set)
Transport & cold chain
Container and trailer door seals, refrigeration unit seals, shock mounts.
What decides the specification
Low temperature and ozone are the usual failure modes; flexibility at −30 °C is a different requirement from flexibility at 0 °C. EPDM and silicone cover most of this range, with the choice set by the low-temperature test data.
What we need from you
- Minimum temperature and time at that temperature
- Ozone exposure in service
- Whether the part must also resist cleaning chemicals
Buyer questions
Do you make parts for automotive programmes?
We make parts that go into automotive-adjacent assemblies, but IATF 16949 is not claimed, so we are not positioned as a tier-one or tier-two automotive supplier. If your programme requires IATF, say so at the start rather than at audit.
Can you work from a sample instead of a drawing?
Yes, for reverse-engineering a replacement part. We measure the sample, produce a drawing for your approval, then quote against the approved drawing. The buyer signs off the drawing, because the drawing — not the sample — becomes the controlled specification.
Do you supply parts for food or drinking-water contact?
Only where a specific compliant compound and its test evidence exist. That is a material approval, not a factory approval, and it is currently not claimed on this site. Name the regulation and the market, and we will answer whether it is available.
What information should an RFQ include?
Drawing, media contacted, continuous and peak temperature, annual volume, destination market, any standard the part must meet, and whether the part is new or a replacement for an existing supplier.
Tell us the failure you are trying to avoid
That is usually a better starting point than a product name. We will map it to a compound and a process.
Request a quote