CONCEPT DEMO· Illustrative structure and copy for a Yixing rubber & plastics manufacturer· Placeholder data marked TO BE CONFIRMED
Home  /  Materials

Choose the compound from the media, not from a preference

Most failed seals are the right geometry in the wrong compound. This page states what each family resists, what attacks it, and what the temperature range means in practice.

Elastomer comparison

Temperature bands are typical service ranges for standard compounds, not absolute limits. A specific formulation can shift them, and verification is by test report, not by this table.

MaterialResistsAttacked byTypical useService range
EPDMWeather, ozone, UV, water, steamPetroleum oils, fuels, aromatic solventsOutdoor seals, HVAC, water and steam service−40 to +120 °C
NBRMineral oils, greases, fuels, waterOzone, sunlight, ketones, strong acidsOil seals, fuel-handling parts, hydraulic−30 to +100 °C
FKM (Viton type)Fuels, oils, solvents, high temperatureKetones, esters, amines, hot water/steamChemical and fuel service, high-temp seals−20 to +200 °C
Silicone (VMQ)High and low temperature, ozoneMany oils and fuels, tear strengthHigh-temp seals, food-adjacent, cold service−60 to +200 °C
CR (Neoprene)Weather, moderate oils, flame resistanceAromatic solvents, strong oxidisersGeneral outdoor and industrial seals−40 to +100 °C
NR (natural)Fatigue, tear, low dampingOzone, oils, heat ageingAnti-vibration, dynamic flexing parts−40 to +80 °C
TPE / TPVRecyclability, colour, soft-touchHigh temperature, some solventsConsumer-facing and co-extruded parts−40 to +120 °C
If your part sees two incompatible media — outdoor weather plus oil, for example — no single standard compound solves it. The honest answer is either a compound change with a trade-off, or a design change. We will say which.

The three questions that decide the compound

1. What touches it?

Name the actual media, including cleaning agents, coolant and lubricants. "Oil resistant" is not a specification; a specific oil at a specific concentration is.

2. How hot, how long?

Peak temperature and continuous temperature are different problems. A short excursion to 150 °C is not the same duty as continuous 120 °C over five years.

3. What must it meet?

A standard number (ISO, ASTM, FDA regulation, WRAS, UL) changes both the compound and the evidence required. Name it at RFQ, not after the first article.

What we mean by "verified"

ClaimWhat has to exist to make it
"EPDM"A compound batch record naming the polymer and cure system
"Oil resistant"A volume swell test in the named medium, with duration and temperature stated
"Food contact"A specific regulation citation plus migration test report, per compound
"−40 °C capable"A low-temperature test (TR10 or brittleness) on the actual compound
"Flame retardant"A UL94 or equivalent classification on a specimen of the compound
Every row above is a document, not a property of the factory. That is why we ask for the standard at RFQ stage: it decides whether the evidence can be produced at all.

Buyer questions

Which material should I choose for outdoor use?

EPDM is the usual starting point for outdoor exposure because of its ozone, UV and water resistance. It is the wrong choice in contact with petroleum oils. If the part sees both outdoor weather and oil, the answer is usually a different compound or a design that separates the two exposures, not a compromise grade.

Is silicone always better than EPDM?

No. Silicone has a wider temperature range but lower tear strength and worse resistance to many oils and fuels, and it costs more. It earns its place in high-temperature or food-contact-adjacent applications, not as a default upgrade.

What does 'food grade' actually require?

A specific compound tested to a specific standard for a specific market — for example an FDA regulation number or an EU framework regulation plus migration testing. It is not a property of a factory, and it cannot be claimed on the strength of the base polymer alone.

Can you supply a compound to my own specification?

Where the specification is complete enough to formulate against, yes. In-house mixing is what makes that possible. If you have an existing compound code, send the property sheet; if you only have performance requirements, we will propose a formulation and state which properties are verified.

Send the media and the temperature range

That is enough for us to shortlist a compound and tell you what evidence can accompany it.

Request a quote